Bolted Connections Calculator

Check the factored shear, bearing, tension, and combined resistance of a single high-strength structural bolt (ASTM F3125 A325M / A490M) to CSA S16.

Standards used on this page:CSA S16-19 Clause 13.12 · shear Vr = 0.60 φb n Ab Fu(×0.70 threads intercepted) · bearing Br = 3 φbr t d Fu· tension Tr = 0.75 φb Ab Fu · φb = φbr = 0.80.
Scope: a single bolt. Shear uses the gross (nominal) bolt area; bearing assumes adequate end/edge distance and spacing (the 3φbr t d Fu form, not the end-distance-limited value). Slip resistance (serviceability, Clause 13.12.2) and block shear are not checked. The S16-19 bearing factor φbr = 0.80 is used (raised from 0.67 in pre-2009 editions), so bearing values differ from older textbooks.
Bolt
Connected plate (for bearing)
Applied factored loads per bolt (optional)
This calculator provides preliminary, indicative structural calculations only, intended to assist with initial sizing and understanding. It is not a substitute for assessment by a qualified structural engineer, and ca.cad-steel.com accepts no responsibility for its use in any final design.